How Many Solar Panels For a CPAP Machine?

CPAP machines are low-power devices ideal for solar. Without the heated humidifier, a CPAP draws just 30-60W. With humidifier and heated tube, plan for 50-100W. For 8 hours of nightly use, that's 240-800Wh. A 200W panel array easily provides this.

Understanding Solar Panel Sizing

Determining the right number of solar panels for your needs is more nuanced than simply dividing your energy requirements by panel output. The actual panel count depends heavily on your geographic location, local climate patterns, and how you plan to use the energy. A homeowner in Arizona might need half as many panels as someone in Seattle for the same energy consumption, simply because of the dramatic difference in annual sunshine hours. Understanding these variables helps you design a system that reliably meets your needs without overspending on unnecessary capacity.

Solar panels work in concert with batteries and charge controllers to form a complete energy system. The panels generate electricity during daylight hours, but your battery bank stores that energy for use when the sun is not shining. This relationship means you cannot size panels in isolation - you must consider your battery capacity, daily energy consumption, and how many days of autonomy you want during cloudy weather. A well-designed system balances panel capacity with battery storage to ensure you have power when you need it, whether that is running essential appliances during a grid outage or powering a remote cabin year-round.

Seasonal variation presents one of the biggest challenges in solar system design. In most locations, winter produces significantly less solar energy than summer due to shorter days and lower sun angles. If you are designing for year-round off-grid use, you must size your system for the worst-case scenario: the shortest, cloudiest days of winter. This often means your system will produce excess energy during summer months, which can be managed through load diversion (like heating water) or simply accepted as part of reliable system design. Grid-tied systems can offset this by drawing from the utility during low-production periods and exporting surplus during peak production.

The distinction between off-grid and grid-tied systems fundamentally changes your sizing strategy. Off-grid systems must be self-sufficient, requiring enough panels and batteries to handle your entire load plus a safety margin for extended cloudy periods. This typically means oversizing by 25-50% compared to average daily needs. Grid-tied systems can be sized more precisely to offset your annual consumption, since the utility provides backup during low-production periods. Hybrid systems with battery backup offer a middle ground, providing resilience during outages while still benefiting from grid connectivity. Your choice between these configurations significantly impacts both the number of panels needed and the overall system cost.

Quick Answer

Minimum

1panels

100W each

Recommended

2panels

100W each

Ideal

2panels

100W each

Daily Need

0.4kWh

Calculation basis: CPAP with heated humidifier running 8 hours nightly

Panels Needed by Size

Based on 5 peak sun hours and 80% system efficiency.

Panel SizeDaily OutputPanels NeededTotal Watts
100W400Wh/day1100W
200W800Wh/day1200W
400W1600Wh/day1400W

Factors That Affect Panel Count

1.Whether you use heated humidifier
2.Heated tube usage
3.Pressure setting
4.Machine efficiency (newer = better)
5.Your location's sun hours
Adjust for Your Location

The calculations above assume 5 peak sun hours (US average). Adjust based on your location:

Southwest US

6-7 peak sun hours

Need ~20% fewer panels

Central/Southeast

4-5 peak sun hours

Use our estimates

Northern/Pacific NW

3-4 peak sun hours

Need ~25-40% more panels

Tips

  • *Disable heated humidifier to cut power draw by 50-70%
  • *Use a DC-DC adapter to skip the inverter entirely
  • *A 100Ah lithium battery runs a CPAP for 3-5 nights without sun
  • *Consider a travel CPAP—they're designed for battery operation
🔋Battery Sizing

For a CPAP Machine, you'll also need battery storage for nighttime and cloudy periods.

Minimum Battery

42Ah

~12 hours autonomy

Recommended Battery

84Ah

~24 hours autonomy

Frequently Asked Questions

Can I run a CPAP on battery backup?

Absolutely. A 100Ah lithium battery can run a CPAP (without heated humidifier) for 3-5 nights. With humidifier, expect 1-2 nights per charge.

What's the best battery for CPAP backup?

Lithium (LiFePO4) batteries are ideal—lightweight, deep discharge capability, and no maintenance. Many travel CPAP batteries are purpose-built for this.

Do I need an inverter for CPAP?

Most CPAPs can run from DC power with the right adapter cable. This is more efficient than using an inverter. Check your CPAP model for 12V/24V compatibility.